REVEAL HOME INSPECTIONS Return
to Home Page Index
Phone 845-526-2499
What is Inspected During a Home Inspection?
|
The Standard of Care for the Home Inspection Profession |
CONTENTS BELOW
SCROLL DOWN - CLICK ON TOPIC
INTRODUCTION and ACKNOWLEDGEMENT
ETHICS
PRE-INSPECTION AGREEMENT
EVALUATING COMPONENTS
THE REPORT
DEFECTS REQUIRE RECOMMENDATIONS
COMPONENTS FOR INSPECTION
The Standard of Care for the Home Inspection Profession is provided to establish a standard by which Home Inspectors should operate their business and by which they may be measured. Following the various sections of the Standard of Care, the home inspector should be able to perform a professional inspection and produce a quality report.
The purpose of a home inspection is to educate the customer about the condition of a home. More specifically it is to inform the customer about major deficiencies in the condition of the home. A home inspection provides a generalists view of the home. To do this, the home inspector performs a visual inspection of the readily accessible portions of the home. The inspector uses the normal operating devices designed for use by the homeowner on a day to day basis. The home inspection does not include invasive procedures and is not technically exhaustive. Then the inspector prepares a written report of the findings for the customer.
Home Inspectors are encouraged to inspect, report and operate their businesses in compliance with these Standards of Care.
States considering legislation effecting Home Inspection are encouraged to adopt these Standards of Care.
ACKNOWLEDGEMENT
Acknowledgement is given to the American Society of Home Inspectors, Inc., the National Association of Home Inspectors, Inc., the North Carolina Home Inspector Licensure Board, the Oregon Construction Contractors Board, the Society of Professional Real Estate Inspectors, the South Carolina Residential Builders Commission and other home inspector groups and organizations for their precursors to this Standard of Care. Without their earlier efforts this comprehensive Standard of Care would not have evolved.
Copyright
This Standard of Care for the Home Inspection Profession is provided in the public domain and, provided it is copied and used in its full context, may be copied and used by people without concern of copyright violation. Should any changes and /or deletions from the entire text be desired or made, then this is fully copyrighted by the Home Inspection Institute of America, Inc., and any repercussions for copyright violation will fall on the persons violating this provision. Reprinting for the purposes of sale is not permitted under the terms of this copyright. December 30, 1998.
Home Inspectors should use good business judgment and ethics in the operation of their business and the conduct of inspections. In this light, the following are critical:
A. Prepare a concise report of conditions as actually observed at
the time of inspection.
B. Avoid conflicts of interest by:
Not releasing the information from the inspection or report to
anyone other than the customer, without the customers written authorization
C. Not discriminate against anyone on the basis of age, creed,
color, sex, sexual orientation, physical or mental handicap, or
national origin.
D. Comply with applicable state laws and regulations.
E. Only inspect homes in which the inspector does not have an
interest in the outcome of any related real estate transaction.
F. Not provide an opinion of the market value of the inspected home.
G. Not allow his or her other interests in any business to affect
the quality or results of the inspection work or report.
H. Not engage in false or misleading advertising or otherwise
misrepresent any matter to the public.
The inspector will use a written contract, Pre-Inspection Agreement, for each and every inspection to be performed. This includes customers, such as lenders, real estate people, consumers buying or selling a home, and others whom might hire a home inspector for a home inspection. The purpose of this document is to educate the customer about what they receive when they purchase a home inspection.
The Pre-Inspection Agreement should be:
A. A written document
B. Executed before the inspection
C. Signed by both a representative of the inspection company and
the customer
D. List those general areas, items or components which will be inspected
E. List those general areas, items or components which will not be inspected
F. Indicate the purpose of the inspection
G. Indicate that the inspection is not a "code inspection"
H. Indicate that it is a visual inspection of things as they
appear at the time of the inspection
I. Indicate that concealed, hidden or otherwise visually
undetectable defects are not included
J. Must be dated
K. Must show the date or intended date of the inspection
L. Must include the price of the home inspection
M. Must fully identify the inspection company and customer with
name, full street address, city and state
N. The address for the inspection must also include full street
address, city and state
The Pre-Inspection Agreement may, if not prohibited by local law:
A. State who has a right to rely on the report. This may limit the
use to the customer.
B. Spell out in detail the arrangement for dispute resolution, in
the event of a dispute between the parties
C. State the maximum liability limit of the inspection company and
its employees and the conditions of the limitations
D. State the maximum time for which the inspection company and its
employees may be held liable
E. May include language to limit claim recovery for negligence and
breach of contract
F. In a state or jurisdiction with direct regulation of the home
inspection profession, as required, provide the appropriate
certification, license or registration number(s) as per the regulations
Home Inspectors evaluate any and all components by following the steps set forth below.
1. Determine the overall, major function of the component being inspected.
2. See if it appears to be doing the overall, major function, as
determined above, in a safe and healthy manner.
3. Look for indications that it is failing or may fail (in the
reasonably near future - varies from component to component) to do
the overall, major function, as determined above.
4. Probe or sound structural components where deterioration is
suspected, except where probing could damage any finished surface.
In order to evaluate these components, inspectors must apply all of their natural senses (sometimes using special tools to extend their senses) to determine the following:
· Does it look right, or not.
· Does it feel right, or not.
· Does it smell right, or not.
· Does it sound right, or not.
· Does it seem right, or not.
Different senses are used to varying degrees during this process.
Only normal operating devices will be used during the inspection. Emergency switches need not be operated. Access panels designed for normal use by a homeowner should be opened. Access panels nailed and screwed closed will not be opened.
Inspections are visual in nature. The inspector evaluates based on what can be observed during the inspection, under the conditions existing during the inspection.
Invasive procedures are not to be performed by the Home Inspector. Invasive procedures should be left to people who specialize in those specific procedures. Some examples of invasive procedures: digging dirt or soil, probing finished surfaces, scraping or digging into rusty surfaces.
The above is the common basis for inspection of each and every component.
The Home Inspector should accurately report what has been observed - nothing more - nothing less - just what has been observed, within the guidelines established herein.
Describe the component by brand and or general make up. Brand names should be reported for major appliances. Structural components would be described by saying the materials of which it is made or of which the exterior covering is made.
Itemize the indicators.
This involves detailing out the evidence, which tells the inspector the condition of a component. An example might be "...clean, bright color , laying smooth, sharp square corners..." to describe a newer looking asphalt composition shingle roof covering.
Estimated ages will be the apparent age (not the actual chronological age) of a component, such as: newer, mid-life, older, beyond end of useful life, very old, et cetera.
The report may be in a narrative format, checklist format or a combination of narrative and checklist. The report may be prepared and delivered on-site or prepared after the inspection. If the report is not delivered on-site, it must be delivered to the customer within 48 hours after the inspection. If the report is to be mailed to the customer, the customer should be so advised, in writing, prior to the execution of the Pre-Inspection Agreement and the inspector should retain a copy of said notice with the report file.
The report must include the following:
1. Apparent age of dwelling
2. General type of building structure
3. Each of the COMPONENTS FOR INSPECTION as spelled out elsewhere in this Standard of Care.
4. Noted indicators of:
a) water penetration
b) differential settlement
c) movement of components not designed to move
d) harmful condensation and other major failure of component inspected
e) major moisture damage
f) evidence observed, if any, of wood destroying insect infestation
g) wood to soil or siding to soil contact
h) serious safety hazards
DEFECTS REQUIRE RECOMMENDATIONS
There are specific procedures for handling the defects or deficiencies found during the inspection. Home Inspectors are to recommend that the proper type of contractor remedy defects. This will educate the customer as to which type of contractor is to be used for the repairs or for further evaluation.
This is a three-step process:
1. Itemize the indicators - requires the inspector to report just
what was observed to indicate to the inspector that there is a defect.
2. Recommend the defect be rectified.
3. Advise the specific type of contractor to be used, without
recommending any contractor by name.
Sometimes, it may be necessary to be general in the type of contractor to recommend, as it may not be possible for the inspector to determine which type of contractor should be hired:
a) Do to the type of work to be performed
b) Because several types of contractors may do the required work
c) Because the severity of the work to be performed may not be determined
until invasive procedures are performed
If the inspector finds a component, which the inspector can not
evaluate, the inspector should recommend the proper type of person be
brought in for further evaluation and/or the necessary repairs.
As the inspector often could easily influence the customer, the inspector is not to recommend individual contractors by name. So doing could pose a conflict of interest.
The inspector is NOT to advise the customer as to how to make repairs.
The Home Inspector should accurately report what has been observed - nothing more - nothing less - just what has been observed, within the guidelines established herein.
The Home Inspector is to visually inspect the components and provide the customer with a written report as to the findings of the inspection, for each component. The procedures for inspecting and reporting are spelled out elsewhere in this Standard of Care.
Following are the general components for inspection:
A. General Structure
B. Basement and/or Lowest Level
C. Central Cooling
D. Central Heating
E. Plumbing
F. Bathrooms and Laundry
G. Electrical
H. Common Safety Devices
I. Kitchen and Kitchen Appliances
J. Fireplaces and Wood Stoves
K. General Interior
L. Attic, Insulation and Ventilation
M. Roof
N. Exterior
O. Grounds
P. Parking
These components are detailed out on the following pages.
This list is not intended to limit the inspector to inspecting only these components, others may be inspected, but the above should be inspected, if possible, by the inspector.
Invasive procedures are not to be performed by the inspector. Some examples of invasive procedures are: moving stored items, furniture and/or debris, unfastening nailed or similarly secured access panels, digging or excavating soil, vegetation or debris, cutting back plant growth. Of course, this prohibits the inspector from looking into the inside of walls, behind finished surfaces, into concealed areas, inside of enclosed areas, into or through insulation, and similarly enclosed spaces. This also prohibits the probing of finished surfaces.
The inspector should enter under floor crawl spaces, basements, and attic spaces, except where access is obstructed or restricted, when entry could damage any property, or when dangerous or adverse situations are present or suspected. If not entered the report must include the reason for not entering.
The inspector is not required to do things or go places where dangerous to the structure or the inspector. Some examples of dangers are: walking on roofs, climbing a ladder more than a few steps off the ground, moving insulation, entering areas where suspected hazardous materials may be, entering unsafe areas such as damp or wet crawl spaces and crawl spaces without sufficient room for the inspector to safely move around.
Where accessible, the inspector shall visually inspect and report on the following general components:
A. Foundation, foundation walls, other support and sub-structure
components, including carrying beams, support columns and piers
B. Enter under floor crawl spaces, basements and attics
C. Floors, basement slabs, grade slabs, first and subsequent
floors (if framing visible), and to include bouncing on the floor to
evaluate the amount of deflection in the floor
D. Exterior walls, for straightness and/or out of the ordinary
deflection, thickness based on window and/or door depth
E. Ceilings, as a reflection of the condition of the floor above
F. Roofs, for major deficiencies and apparent age of roof covering
(not years but where in useful life it may be)
The inspector should probe structural components, if deterioration is suspected or observed, provided such probing will not damage the component. Probing is not required on finished surfaces, as so doing will damage the finish on the surface.
The inspection will be made in accessible areas of the basement and crawlspaces and form the exterior and interior.
Many of the above components will be addressed in more detail in other sections of the Components for Inspection.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Foundation walls and other visible foundation components for
material of manufacture, cracking indicating movement, including
differential settlement or movement, other structural failure,
leakage and water penetration and moisture damage including efflorescence.
B. Where the interior of the foundation is hidden by wall framing
and/or coverings, the framing and/or coverings should be inspected
for evidence similar to that in (A) above.
C. Walls, other support and sub-structure components, including
carrying beams and support columns for indications of deflection,
movement, significant rot or other deterioration.
D. Wooden structural components for visible damage by wood
destroying insects, major areas of rot or damage from wood destroying
organisms. This is not to replace a thorough inspection by an
appropriately credentialed or licensed wood destroying insect expert.
E. Basement floors, basement slabs, grade slabs and garage floor
slabs for cracking and water penetration, evidence of flooding,
drainage provisions, and other indicators of failure of the flooring
materials. Included would be provisions for installed sump pumps.
F. Ventilation or provision for ventilation of enclosed areas.
G. Exterior egress from normally useable spaces, for safety.
H. Walls and floors for evidence of general dampness.
I. First and subsequent upper level floors (if framing is visible)
for damaged components and noticeable deflection. Bounce on the floor
to evaluate the amount of deflection in the floor.
J. Exterior walls, for straightness and/or out of the ordinary
deflection, thickness based on window and/or door depth.
K. Ceilings for cracking and/or out of the ordinary deflection, as
a reflection of the condition of the floor above.
L. Wood or siding to soil contact, which may be conducive to
insect infestation or rot.
The evaluation of these structural components are not structural engineering evaluations, but rather, inspections looking for evidence of a need for possible further evaluation by an engineer or other specialist.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Brand name on unit
B. Type of unit, such as central air, heat pump, gas chiller,
evaporator, roof mounted water conditioning equipment
C. Open readily operable access panels provided by manufacturer or
installer for routine homeowner maintenance
D. Operate the unit, provided outside air temperature has been
above 60 degrees Fahrenheit for at least the prior 24 hours
E. Evaluate visually the condition of visible components
F. Check for distribution within living space of home
G. Attempt to determine if distribution system is in common with
or separate form central heating system distribution system
Individual room units and window units need not be evaluated as part of the inspection.
Efficiency, uniformity and/or adequacy evaluation of the unit is beyond the scope of this inspection.
Any system covered for the off season need not be inspected, but such conditions should be reported.
Only readily accessible panels provided by the manufacturer or installer for routine homeowner maintenance shall be opened. Screws, bolts, nuts and other fasteners are not to be undone, as these are in the purview of the specialized contractor.
In the report, not indicators of failing components, leaks, excessive rust or corrosion, or soot stains around registers.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Brand
B. Fuel type, such as gas, oil, electric, coal
C. Fuel storage and/or entry location and look for evidence of leaks
D. System type, such as forced hot air, forced hot water, gravity
hot water, radiant, steam, electric baseboard, heat pump
E. Apparent age (such as newer, older) and how determined
F. Presence of controls, such as thermostats, electric and fuel
automatic or emergency shut off devices
G. Operate heating unit by use of thermostat(s), only, to see if
unit does operate
H. Heat exchanger, since this is hidden from view, look for
evidence of it being defective without actually being able to view
the unit itself
I. Flue and vent pipes, connections, pitch up toward chimney and deterioration
J. Heat distribution system by operating and checking for heat
distribution at distribution points throughout the home in areas
where heat distribution would be expected. Report any living spaces
that are not heated.
K. Where visible, check for deteriorated, loose, broken,
disconnected and unsupported components
L. Checks for presence or absence of filters, if readily
accessible check for cleanliness and installation of air filters
M. Humidifier on a system can not be checked for effectiveness of
unit but leaks and loose parts should be reported
N. Permanently installed supplemental heat systems should be
reported and operated, when possible
O. Report any observed safety hazards
The evaluation of the heating system is not as in depth as a heating contractor would make.
A Heat Pump need not be operated in the heating mode, if the outside temperature has been above 75 degrees Fahrenheit the past 24 hours or if other weather conditions prohibit.
The operation of automatic safety controls and devices is excluded.
Only readily accessible panels provided by the manufacturer or installer for routine homeowner maintenance shall be opened. Screws, bolts, nuts and other fasteners are not to be undone, as these are in the purview of the specialist-heating contractor.
On the report, note indicators of failing components, leaks, excessive rust or corrosion on water systems and soot stains on and around registers on air systems.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Water Service
Main supply line material and point of entry
B. Waste System
Piping materials, main waste line clean outs
C. Domestic Water Heating
Fuel type
D. Kitchen sink(s) for leaks, drainage, stoppers
E. Garbage disposal for leaks and operation
Where accessible, this inspector shall visually inspect and report on the following components:
A. General location of each bathroom within the home
B. Whether full or partial
C. Sinks for operation of faucets, drains and stoppers and for
secure fastening to structure and for type or style, such as wall
hung, vanity or pedestal
D. Toilets, for operation of flush, and for secure fastening of
components and for secure fastening to floor or wall
E. Bidets for operation and secure fastening
F. Tub for drain, water supply, and being secured in place and
type, such as built-in, leg tub
G. Showers, for function, and location, such as with tub, stall shower
H. Surrounds, especially those permanently installed, for
tightness of installation and material of which made and general condition
I. Leak evidence form (A) through (F) above
J. Floor covering for material of manufacture and conditions
requiring immediate correction
K. Condition of caulking around sinks, tubs and showers at walls
and floors
L. Evidence of excessive mildew indicating a lack of ventilation,
under present usage
M. Ventilation for type, if fan to try to determine to where it vents
Laundry
Where accessible, the inspector shall visually inspect and report on the following components:
A. Clothes washer
General age
B. Clothes dryer
General age
If not inspected, report reason not inspected. Report if connections were found, if not inspected.
Report the general location of the laundry within the home.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Service lines
For type; such as overhead or underground
B. Meter
For rating of class, voltage, and number of wires
C. Disconnect
For amperage
D. Main Panel
For rated maximum load in amperes
E. Evaluate the above to see if they are compatible. Acceptable
answers are "YES." "NO," or "NOT SURE,"
especially if all four can not be determined.
F. Grounding
For existing
G. Sub Panels
For number
H. Main and Sub Panels
For being secured to building
I. Outlets, randomly test
For type, two or three prong, polarized or not
J. Switches, randomly test
For what they operate
K. Permanently installed lighting fixtures
To see if they come on when turned on
L. Other wiring
For being secured to building
Any other unsafe electrical conditions observed should be reported.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Ground Fault Interrupter protection devices
For their existence in normally wet areas, such as near sinks,
bathrooms, laundry areas, garages, on exterior of home
B. Smoke Detectors
For their existence in the home
C. Carbon Monoxide (CO) Detectors
For their existence
D. Fire Suppression Sprinkler Systems
For their existence
Report how the safety device was tested. If not tested, report why.
The inspector does not make code determinations as to number and placement of these devices. Any such concerns should be directed to the code officials of appropriately licensed contractors.
If there is an alarm system in the home, try to determine if alarmed to off premises and if so, do not test but recommend that an alarm company evaluate before sleeping in the home.
Carbon Monoxide Detectors are not tested with an external testing device due to the nature of the devices.
Fire Suppression Sprinkler Systems are not tested, because to test would be to create flooding.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Permanently installed Cabinets
For presence or absence
B. Permanently installed Countertops
For presence or absence
C. Floor
For type of floor covering
Kitchen Appliances
The inspector should determine from the customer those major appliances to be checked (or check them all). Then, where accessible, the inspector should visually inspect, operate and report on the following components, checking ONLY the operation of major functions:
A. Dishwasher
For brand
B. Refrigerator
For brand
C. Range/cooktop
For brand
D. Oven
For brand
E. Ventilation
For brand
F. Built-in Microwave
For brand
Appliances are evaluated for the major function, only.
The customer may instruct the inspector not to inspect any appliance.
The inspector does not report on the cleanliness of appliances.
The operation of clocks, timers, self-cleaning functions and/or any evaluation of thermometers are excluded.
Non-built-in major appliances and minor appliances are excluded.
Trash compactors need not be operated.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Fireplaces
For location
B. Wood stoves
For location
As with other components, this is not a code inspection but is rather a general inspection for general safety.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Ceilings
For material of surface
B. Walls
For material of surface
C. Floors
For material of major area floor coverings
D. Doors, interior
For type
E. Windows
For type
F. Skylights and roof windows
For type
G. Stairs
For tread being secure
H. Balconies
For handrails
The inspector should randomly operate doors and windows to evaluate their operation. The inspector can not be expected to reach and operate every single one.
Attic, Insulation and Ventilation
Where accessible, the inspector shall visually inspect and report on the following components:
A. Attic
For access and type of access
B. Insulation
Where visible in readily accessible spaces and/or unfinished spaces
In attic
C. Ventilation
Attic
The inspector is performing a general inspection and is not doing a formal energy audit or evaluation, as part of a regular home inspection. The inspector can not be expected to report on insulation and ventilation in concealed spaces. Ventilation equipment that is integral with household appliances is excluded, except that the inspector will be expected to operate normal operating devices.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Roof covering
For style of roof design, such as gable, hip mansard, gambrel,
flat, shed
B. Roof decking for deflection, holes, rot and other damage
C. Skylights for condition on exterior
D. Roof penetrations, such as antenna, chimneys, trap doors, and
vent pipes for condition
E. Roof framing for deflection, broken members, rot and other damage
F. Visible flashing
From exterior
G. Roof drainage
From exterior
The normal roof inspection of a sloped or pitched roof is done from the ground, using binoculars. The inspector is not required to climb up to or onto a roof. For a flat roof with access from the interior, the inspector would normally observe the roof from this access opening, if safe. The inspector may recommend a roofer evaluate areas that the inspector can not inspect following these procedures.
Report the method used to observe the roof components.
Report those sections of roof not visible from the ground.
Where accessible, the inspector shall visually inspect and report on the following components:
A. Wall covering
For apparent material of manufacture
B. Trim, eaves, soffits, and fascias
For apparent material of manufacture
C. Doors, exterior
For more than one exit from home
D. Windows
For storms and screens, as applicable to area or type of window
E. Skylights and roof windows
For patching and damage
F. Chimney(s)
For number
G. Main entry porch
For location
H. Other porches
For location
I. Decks and balconies
For access below
J. Environmental, very limited
For obvious environmental concerns, such as dark stains on soil,
oil slicks or stain on water (ponds or lakes on property), abondoned
motor vehicles, paint cans, out of use storage tanks, abandoned
batteries, pipes into ground which might indicate buried tanks
Where accessible, the inspector shall visually inspect and report on the following components that are close to the home:
A. Grading
Within about 5 to 10 feet of foundation
B. Driveway(s)
For location and material of construction
C. Sidewalks and walkways
For location and material of construction
D. Patio
For location and material of construction
E. Window wells
For material of manufacture
F. Trees and other plantings for negative effects on building
For touching home
G. Retaining walls
For material of manufacture
H. Fences
Limited to major fences, NOT small, low decorative fences
Where accessible, the inspector shall visually inspect and report on the following components:
A. Garage
For type, such as built into house, attached, detached, semi-detached
B. Carport
For type, such as attached, detached
C. Other
For type, off street, on street
The home inspector is a generalist, not a specialist, and therefore performs a general inspection. A technically exhaustive inspection is not performed by the home inspector, but rather by a specialist in a particular trade or profession and is generally limited to one component of a home and not the whole home.
The inspector is performing a visual inspection, using the natural senses, to observe the structure and major components of the home. Sometimes the inspector may use special tools as an extension of the senses.
In general the home inspection applies to the inspection of four dwelling units or fewer, but may include inspections of common-ownership property, such as condominium units and complexes and co-operatives.
Home inspectors are not required to:
1. Enter any area believed to contain materials or conditions
hazardous or unsafe for the inspector.
2. Move personal belongings, stored items, plant life, furniture
or anything else which blocks or may block the viewing of components.
3. Perform any excavation to view components, including removal of
leaves, snow and ice.
4. Remove debris to make observation.
5. Enter spaces with headroom less than 3 feet.
6. Perform invasive procedures.
7. Inspect any area blocked by finished surfaces and concealed
areas, framing or insulation.
8. Poke or probe finished surfaces when such action could damage
the finished surface.
9. Report or estimate life expectancy of components. The inspector
may render an opinion regarding where a component may be in its
expected life.
10. Report on the reasons or cause of damage.
11. Report on the presence or absence of wood destroying insects
or organisms, but, may if observed so report. If observed and
reported the home inspector should not advise on the treatment of
wood destroying insects or organisms, but rather recommend a licensed
pest control person be hired.
12. Report on, or find, potentially harmful substances and
environmental items, such as radon, carbon monoxide, lead, lead-based
paint, asbestos, toxins, carcinogens, noise, urea formaldehyde, water
quality, toxic or flammable chemicals or gasses and water and water
and airborne hazards.
13. Evaluate acoustical characteristics of any system or component.
14. Report anything more than the existence of swimming pools,
fountains and the like.
15. Report on anything other than output from wells. The inspector
should run the water in the home performing a user flow evaluation.
The inspector should not open the well, remove the pumping hoses, the
pump, any pump wires or any other parts of the well. Pumps in the
home will only be observed but not disturbed.
16. Operate free standing or built-in appliances attached to the
water supply.
17. Evaluate shower pans for leakage.
18. Determine or evaluate flow and supply and drain water other
than functional flow.
19. Report on water conditioning equipment, as the valuation
requires special tools, testing and expertise.
20. Inspect foundation drains and other buried items, such as
pipes, foundation walls, electrical lines or building components.
21. Determine if the home sewage goes to a public or private
disposal system, as the piping from the home is usually buried below ground.
22. Evaluate gas lines for other than visible obvious deficiencies.
23. Report on low voltage systems, security systems, central
vacuum systems, fire sprinkler systems (other than their existence),
lawn sprinkler systems, and other safety equipment.
24. Check or search any municipal records or data.
25. Determine compliance with or certify for past or present
governmental codes, rules or regulations pertaining to the home or
land on which built. This includes building codes. Code compliance
(inspection) is not possible because of the ever-changing nature of
the codes (and their vast number) and the different interpretations
of the codes by the building code officials of the local jurisdiction.
26. Report on or find latent, hidden and concealed defects or deficiencies.
27. Climb or walk on the roof.
28. Report on any components that can not be readily observed.
29. Determine method, materials and/or costs of repair or
correction of deficiencies.
30. Evaluate the financial status of any common ownership types of properties.
31. Determine the boundaries of a piece of land, as land surveyors
do this.
32. Determine the value of the home or property, as real estate
appraisers do this.
33. Report about surrounding properties or homes.
34. Counsel on the advisability of purchase of the home or property.
35. Report on cosmetic items.
36. Operate cooling systems if the outside temperature has been
below 60 degrees Fahrenheit during the preceding 24 hours.
37. Operate the heating portion of heat pumps if the outside
temperature has been over 75 degrees Fahrenheit.
38. Inspect non-central cooling devices.
39. Inspect gas-fired refrigeration systems and evaporative
coolers and roof mounted water conditioning cooling systems.
40. Evaluate pressure of coolant, presence or absence of coolant leaks.
41. Determine the efficiency of a heating or cooling unit.
42. Determine the draw of electrical components as HVAC or
electrical contractors do this.
43. Operate any heating, electrical or cooling components when the
inspector determines it may not be safe to do so. However, the
inspector should report the reason s/he feels it is unsafe to do so.
44. Operate automatic safety controls.
45. Dismantle any equipment, controls, gauges or components.
46. Operate or activate any components that are de-activated, shut
down, winterized, secured off or which do not respond to normal
operating devices.
47. Ignite or extinguish any solid fuel fires.
48. Evaluate adequacy of draft or perform a chimney smoke test or
inspect interior of flues including chimneys.
49. Evaluate the installation of any inserts or other
modifications of a fireplace, stove or chimney.
50. Determine clearance to combustibles around heat sources.
51. Evaluate the operation of humidifier, air purifiers, motorized
dampers, heat reclaimers, ionizers and the like.
52. Evaluate solar heating systems or cells.
53. Determine the type of insulation or wrapping materials on
pipes, ducts, boilers or jackets.
54. Operate digital-type or computerized thermostats or controls.
55. Observe the interior of flues, fire chambers, heat exchangers,
humidifiers, filters.
56. Evaluate the adequacy or uniformity of heat or cooling to
various rooms.
57. Inspect equipment, remove covers or panels that are not
readily accessible.
58. Evaluate the effectiveness of anti-siphon devices.
59. Operate any plumbing valves other than normal operating
devices, such as faucet handles at sinks and toilet flush valves.
60. Inspect internal gutter and downspout systems and related
underground drainage piping.
61. Determine where drain piping in 59 above discharges.
62. Insert any tool, probe, or testing device inside the electric
main or sub-panels.
63. Test or operate any over-current devices except ground fault
circuit interrupters.
64. Dismantle any electrical device other than to remove the
covers from main and sub-panels.
65. Activate electrical systems or branch circuits that are not energized.
66. Test each and every switch, receptacle and fixture. Only
random testing will be conducted.
67. Remove switch or outlet cover-plates.
68. Inspect low voltage systems or relays, smoke and heat
detectors (other than as required elsewhere), telephone systems,
security systems, locking devices, cable TV, or intercoms.
69. Inspect burglar alarms, antennas, de-icing tapes, lightening
arrestors, timers or systems controlled by timers, or any other
ancillary electrical components not a part of the primary electrical
distribution system of the home.
70. Operate appliances except as required elsewhere.
71. Evaluate paint, wallpaper and other finish treatments on
interior walls, ceilings and floors.
72. Inspect carpeting, draperies or drapery hardware, blinds and
other window treatments.
73. Lift or move existing floor coverings.
74. Report on concealed insulation or vapor retarders or evaluate
insulation hidden from view.
75. Evaluate venting systems built into appliances.
76. Enter into attic spaces without provisions for walking safely.
77. Walk or crawl across exposed floor joists or try to find
footing hidden by attic insulation.
78. Enter attic or other spaces that are not readily accessible.
79. Break or otherwise damage a surface finish or weather seal on
or around access panel and covers.
80. Inspect concealed areas, framing or insulation.
81. Enter attics areas that are overheated (over 100 degrees Fahrenheit).
82. Evaluate storm windows, storms doors, screens, shutters,
awnings and other seasonal accessories.
83. Evaluate fences.
84. Evaluate safety glazing in doors and windows.
85. Evaluate geological conditions, soil conditions, recreational
facilities, outbuildings other than primary garages and carports.
86. Evaluate garage door operator remote control devices.
87. Offer or perform any act or service contrary to law.
88. Offer warranties or guarantees of any kind.
89. Offer or perform engineering, architectural, plumbing,
electrical or other job function requiring an occupational license in
the jurisdiction where the inspection is taking place, unless the
inspector holds such license. In which case, he/she may so advise the
client and go beyond the Standard of Care for home inspectors as an
extra service. An extra fee may be charged for the extra service.
90. Calculate the strength, adequacy, or efficiency of any system
or component.
91. Project operating costs of any components.
92. Predict future conditions, including but not limited to life
expectancy and failure of components.
93. Report on or determine the source or cause of odors.
Phone 845-526-2499